Home › Brands › Cobetter
Cobetter

Cobetter

Hangzhou Cobetter Filtration Equipment Co., Ltd. · Hangzhou, China · Founded 2003

Filtration and single-use from one manufacturer

About

A manufacturer specializing in filtration and separation materials, founded in Hangzhou in 2003. It produces in-house the entire fluid path of biopharmaceutical processes, from sterilizing filtration and virus removal filters, depth filters, and TFF cassettes and hollow fibers to single-use bags and assemblies and integrity testers. It has overseas subsidiaries in Japan, Korea, Taiwan and Singapore.

Products

Product Lines

Filtration & Separation
  • Viruclear™ virus removal filters
  • Roheap™ CSD depth filters
  • TFF cassettes · hollow fiber filters
  • Sterilizing-grade liquid filters (PES · PVDF) · gas filters
  • Membrane chromatography
  • Syringe filters · centrifugal filters (for laboratory use)
Fluid Management (Single-Use)
  • Lifecask™ RG single-use bioreactor bags
  • Lifecube™ single-use assemblies
  • 2D · 3D bags, tubing · connector assemblies
  • Aseptic filling assemblies · PUPSIT
Filtration Equipment
  • Biophsep™ MiniLab TFF system
  • Certitest™ filter integrity tester
Fluid Management Equipment
  • Convemate™ 4-piston diaphragm pump
  • Lifemeta™ tube welder · sealer
How to choose

Product Selection Information

Sterilizing-Grade Filters
Cobetter · Filtration & Separation

Sterilizing-Grade Filters

Ask About Sterilizing Filter Selection
Main Uses
  • Sterilizing-grade filtration of process liquids
  • Sterilizing-grade filtration of gas lines (gas filter series)
  • Laboratory-scale filtration (syringe filters · centrifugal filters)
Selection Criteria
  • Fluid: media · buffers · intermediates · final bulk; liquid or gas
  • Membrane material and its chemical compatibility with the fluid · adsorption characteristics
  • Size and format: specifications matched to throughput and installation method
  • Sterilization method and integrity test method
  • Technical documents to request: validation guides · extractables data · certificates of analysis
Confirmed Specifications & Options
  • Membrane materials for liquids: PES · PVDF
  • Product series for liquids: DPSTF(PES) · DLHPVDF/LHPVDF · APSBR · SPSHR
  • Sterilizing-grade series for gases: DGPFMP/GPFMP · HSGPFP
  • For laboratory use: syringe filters · centrifugal filters
What to Tell Us
  • Type and composition of the fluid to be filtered
  • Throughput per batch and target filtration time
  • Process stage and sterilization method
  • Filter and housing specifications currently in use
  • Scope of technical documentation needed
Cobetter · Filtration & Separation

TFF Cassettes · Hollow Fiber Filters

Ask About TFF Filter Selection
Main Uses
  • Cassettes and hollow fiber filters for tangential flow filtration (TFF) processes
  • Laboratory-scale TFF (Biophsep™ MiniLab TFF system)
Selection Criteria
  • Format: cassette or hollow fiber
  • Size of the target substance and the matching molecular weight cut-off · pore size
  • Membrane material and the target substance's adsorption · shear sensitivity
  • Membrane area: based on throughput and process time
  • Fit compatibility with existing holders and systems
Confirmed Specifications & Options
  • Formats: TFF cassettes · hollow fiber filters
  • Related equipment: Biophsep™ MiniLab TFF system
What to Tell Us
  • Type and molecular weight · size of the target substance
  • Process volume, target concentration factor and number of diafiltration exchanges
  • TFF system · holder currently in use
  • Specifications of the membrane currently in use
  • Process scale: laboratory · pilot · production
Cobetter · Filtration & Separation

Virus Removal Filters (Viruclear)

Ask About Virus Filter Selection
Main Uses
  • Virus removal filtration step in biopharmaceutical processes
  • Viruclear™ virus removal filter series
Selection Criteria
  • Target product: protein type · concentration · buffer composition
  • Size range of the viruses to be removed
  • Whether prefiltration (a prefilter) is needed
  • Scale: from small formats for process development to production sizes
  • Technical documents to request: virus removal study data · integrity test method
Confirmed Specifications & Options
  • Product series: Viruclear™ virus removal filters
What to Tell Us
  • Type · concentration · buffer composition of the target product
  • Throughput per batch and target process time
  • Virus filter currently in use
  • Virus removal validation plan · schedule
  • Process stage: development · clinical · commercial production
Cobetter · Single-Use & Fluid Management

Single-Use Bags · Assemblies

Ask About Single-Use Configurations
Main Uses
  • Single-use bioreactor bags
  • 2D · 3D bags and tubing · connector assemblies
  • Aseptic filling assemblies · PUPSIT configurations
Selection Criteria
  • Use: storage · transfer · culture · filling
  • Volume and format: 2D or 3D
  • Port · tubing · connector · filter configuration
  • Compatibility of fluid-contact materials with the process fluid
  • Documents to request: extractables · sterilization · integrity data
Confirmed Specifications & Options
  • Lifecask™ RG single-use bioreactor bags
  • Lifecube™ single-use assemblies
  • 2D · 3D bags
  • Tubing · connector assemblies
  • Aseptic filling assemblies · PUPSIT
What to Tell Us
  • Use and process stage
  • Volume and quantity needed
  • Connection method: tubing size · connector type
  • Drawings, or the assembly configuration currently in use
  • Scope of quality documentation needed

Cobetter Quote & Technical Inquiries

Tell us your process stage and the product lines you need, and our technical specialists will respond quickly. TEL +82-2-6409-9338 · info@b2bio.co.kr

Contact Us
↑