A downstream purification equipment manufacturer founded in Suzhou Industrial Park in 2011. It makes i-Axi columns that automate column packing, its in-house developed iBio quaternary diaphragm pumps, and TFF · hollow fiber filtration systems and chromatography systems built on these pumps. Because it develops its pumps and control software itself, columns, pumps and systems can be configured from a single manufacturer.



Product Lines
i-Axi automated chromatography columns
- Inner diameter 296–1,600 mm · maximum pressure 3 bar
- Motor-driven adapter · inflatable seal · slurry valve · tilter
- Packing Station packing controller (Level I to III)
EASY-AXI manual columns
- Inner diameters 50 · 70 · 100 · 140 · 200 · 300 · 450 mm
- In-place replacement of the bottom frit · adapter lift for 300 mm and above
iBio quaternary diaphragm pumps
- L for transfer · I-A for filtration · II-S for chromatography
- 30 L/h class to 4,400 L/h class · up to 6 bar
- Pump head SS 316L · seals EPDM
TFF · hollow fiber filtration systems
- Laboratory VersaFlow 60 · 100 · 150
- Manual iBio Manual TFF (holders 0.5–2.5 m²)
- Automated process TFF 600–10T (60–10,000 L/h)
Chromatography · Process Systems
- iBio chromatography systems (manual · automated)
- Slurry tanks · stirred columns
- In-line dilution · virus filtration · alkaline lysis systems
What RJ Bio Equipment Does in the Purification Process
Column chromatography and TFF are the core steps of downstream purification of biopharmaceuticals. In these steps, RJ Bio equipment divides the work among column packing, liquid transfer, and filtration and chromatography operation. Since each device has a different role, you can configure only the scope your process needs.
| Device | Role in the process | Representative products |
|---|---|---|
| Automated column | Fills resin and compresses it axially to form the column bed. Repacking and unpacking are also done inside the column. | i-Axi (inner diameter 296–1,600 mm) |
| Packing controller | Controls the column's adapter · seal · slurry valve · tilter to run the packing sequence | Packing Station Level I ~ III |
| Chromatography system | Runs and records equilibration · sample loading · washing · elution with the packed column | iBio chromatography systems (manual · automated) |
| Pump | Delivers process liquid at a set flow rate · pressure | iBio quaternary diaphragm pumps |
| TFF system | Concentrates and exchanges buffer using membranes | VersaFlow · iBio Manual TFF · automated process TFF |
i-Axi Automated Columns: Packing Inside the Column
i-Axi moves the top adapter with an electric motor to compress the bed to a set height. The inflatable seal can be opened and closed at any height, resin is loaded and removed through the slurry valve, and the tilter tilts the column to remove air bubbles. According to the manufacturer's website, in-place packing and repacking take less than 2 hours, including preparation and cleaning.
Resin loading
Loads resin slurry through the slurry valve
Remixing
Blows air in from the bottom to mix the resin evenly
Bubble removal
Tilts the column and opens the seal to remove bubbles above and below the frit
Axial compression
Lowers the adapter to compress the bed to the target bed height
TFF · Hollow Fiber: Built from Pumps and Pressure Control
A TFF system pumps liquid from the tank to the membrane, returns the retentate to the tank, and sends the permeate that has passed through the membrane out of the system. Transmembrane pressure (TMP = (PT1 + PT2) / 2 − PT3) is calculated from the feed (PT1) · retentate (PT2) · permeate (PT3) pressures and adjusted with a pressure control valve (PCV) on the retentate side. RJ Bio builds its systems by adding the required sensors and valves to its own quaternary diaphragm pumps.
| Component | Role | Supply status |
|---|---|---|
| Quaternary diaphragm pump · controller | Sends feed to the membrane and operates in speed · constant-pressure · TMP modes | Included as standard |
| Pressure sensors PT1 · PT2 · PT3 | Measures feed · retentate · permeate pressure, calculates TMP | Depends on configuration · optional |
| Pressure control valve (PCV) | Controls TMP by adjusting the retentate-side pressure | Select |
| Flow meter · conductivity · pH · UV · balance | Monitors permeate flow, buffer exchange progress and degree of concentration | Select |
| Cassette · hollow fiber holder | Holds and connects the membrane module | Depends on configuration |
| Membrane cassette · hollow fiber module | The membrane that actually does the filtering. Compatible formats and scope of supply are confirmed through consultation | Depends on configuration |
Applications Confirmed in the Documentation
- Manufacturer's catalog: downstream purification equipment for R&D and production of monoclonal antibodies · vaccines · blood products · recombinant proteins
- VersaFlow user manual: chromatography · ultrafiltration · virus removal filtration of biological macromolecules such as monoclonal antibodies · recombinant proteins · vaccines · gene therapies · blood products
- Scale: from the laboratory VersaFlow (0–150 L/h) to automated process TFF (up to 10,000 L/h) and automated columns up to 1,600 mm inner diameter
Selection Consultation Tailored to Your Process Conditions
Tell us as much as you know about your sample, throughput, column size or membrane area, and the equipment you use now, and B2BIO will work with the manufacturer to sort out the models · options · separately required items for you. Demo arrangements and schedules are also provided after consultation.
Specifications by model · videos · catalog: B2BIO RJ Bio product page ↗
Product Selection Information

i-Axi automated chromatography columns
Main Uses
- Packing, repacking and unpacking of process columns for protein and antibody purification
- Repeatable packing with the same method in process development and production
- Processes with frequent resin changes
Selection Criteria
- Column inner diameter · bed height: required resin volume and flow rate
- Resin type and particle size: choice of filter mesh (10 · 20 µm)
- Tube material: glass (300) · acrylic (450 and above) · SS 316L
- Scope of automation: Packing Station Level I (wizard) to Level III (automated resin transfer · bubble removal · packing · CIP rinsing)
- Installation ceiling height · floor load · compressed air · 380 V power supply
Confirmed Specifications & Options
- Inner diameters 296 · 450 · 600 · 800 · 1,000 · 1,200 · 1,600 mm (specification table on the manufacturer's website)
- Maximum pressure 3 bar; 6 bar pressure-rated tubes made to order
- Operating temperature 4–40 °C
- Slurry valve: single type (economy) · standard type
What to Tell Us
- Resin to be used and target bed height
- Column inner diameter or resin volume
- Packing frequency and desired scope of automation
- Chromatography system used for purification runs
Main Uses
- Ultrafiltration concentration of proteins and antibodies
- Diafiltration (buffer exchange)
- Filtration with hollow fiber modules
- Evaluating TFF conditions at laboratory scale (VersaFlow)
Selection Criteria
- Process volume · target concentration factor · number of diafiltration volumes
- Membrane format (cassette · hollow fiber) and membrane area
- Level of control: manual pressure monitoring, or automatic constant-pressure · TMP control
- Measurements to record (flow rate · conductivity · pH · UV · weight)
- Wetted materials (SS 316L · EPDM) and cleaning conditions (0.5 M NaOH recommended inside the pump, 1 M maximum)
Confirmed Specifications & Options
- VersaFlow 60 · 100 · 150 (0–150 L/h, pressure sensors 0–6 bar, 220 V)
- iBio Manual TFF: holders 0.5–2.5 m², 3/4" piping
- Automated process TFF 600–10T: 60–10,000 L/h, membrane area 0.5–20 m², 6 bar
- Optional: pressure sensors PT2 · PT3, PCV, flow meter, pH · conductivity · UV, balance
What to Tell Us
- Sample and process volume
- Membrane to be used (cassette · hollow fiber) and its area
- Target concentration factor · number of buffer exchanges
- Required measurements and records
Main Uses
- Process liquid transfer
- Feed pump for TFF · hollow fiber
- Pump for chromatography systems
Selection Criteria
- Flow rate range and back pressure
- Application: transfer (L) · filtration (I-A) · chromatography (II-S)
- Number of pressure sensors · flow meter · UV · pH · conductivity
- Shear-sensitive samples to be confirmed by a trial run
Confirmed Specifications & Options
- Flow-rate models 30–4400 (30 L/h class to 4,400 L/h class)
- Up to 6 bar (20 °C), accuracy ±2 % (except iBio L)
- Pump head SS 316L, seals EPDM, diaphragms EPDM / PP
- Cleaning with 0.1–1 M NaOH, sterilization at 121 °C
What to Tell Us
- Required flow rate range and back pressure
- Liquid type · temperature
- Cleaning · sterilization method
- Required control · records
Main Uses
- Purification runs and records with process columns (i-Axi · EASY-AXI)
- Evaluating conditions at the process development stage
Selection Criteria
- Flow rate range (column size and linear velocity)
- Manual (semi-automated) or automated (method-based operation)
- Number of inlets · outlets, and whether gradients are needed
- UV wavelength, pH · conductivity before and after the column, data recording
Confirmed Specifications & Options
- Flow-rate models 30–4400 (1.5–5,000 L/h, manufacturer's catalog)
- Optional: UV (single 254 / 280 nm · multi-wavelength), pH · conductivity, flow meter, bubble trap · bubble sensor
- Automated type: 2–8 inlets · outlets, isocratic · gradient pumps, 1–3 pressure sensors
What to Tell Us
- Column size and flow rate
- Required number of inlets · outlets
- Measurements and recording requirements
- Installation space · power supply