A bioprocess equipment manufacturer founded in Suzhou in 2017. Centered on its lab protein purification systems AutoPreS · AutoPure, it makes process equipment at every scale: pilot · production chromatography (Pilot600 · AutoPure Process), automated TFF systems (AutoTFF), oligo synthesizers (AutoOligo), preparative HPLC (AutoPrep), LNP production systems (AutoMCD) and bioreactors. B2BIO Inc. is the exclusive distributor in Korea for Inscinstech.



Product Lines
Lab protein purification — AutoPreS · AutoPure
- AutoPreS — single pump, 0.001 ~ 15 mL/min, 27.5 MPa
- AutoPure 25 · 100 · 150 · 300 — two-pump gradient, up to 25 ~ 300 mL/min
- UV · conductivity · temperature standard; multi-wavelength UV · pH · fraction collector optional
Lab purification — AutoPreD · NestoPure · NestoPro · NestoPure HT
- Other configurations in the same flow-rate range as AutoPure
- NestoPure HT — 8-channel independent parallel purification
Pilot · production purification — Pilot600 · Pilot600D · AutoPure Process
- Pilot600 · 600D — 1 ~ 600 mL/min per pump, 2 MPa, column inner diameter 26 ~ 200 mm
- AutoPure Process180 · 600 — 10 ~ 180 · 10 ~ 600 L/h, 0 ~ 6 bar
IMC manual chromatography columns · column packing consultation
- Inner diameter 72 ~ 296 mm, tube height 500 · 750 · 950 mm
- Glass tube, maximum pressure 7 ~ 4 bar (by inner diameter)
- Column packing · re-packing: case-by-case consultation depending on resin · column size · application
AutoTFF automated TFF systems
- AutoTFF075 · AutoTFF3 — laboratory, membrane area 50 cm² ~ 0.1 · 0.5 m²
- AutoTFF Pilot10 — pilot, 0.1 ~ 2.5 m²
- AutoTFF Process — custom-built for production
AutoOligo oligo synthesizers
- NestoOligo MC-16 — 16 channels, 10 nmol ~ 20 µmol per column
- AutoOligo 25 ~ 150 — 10 µmol ~ 12 mmol
- AutoOligo 600 · 2000 · Process — 1 mmol ~ 1,800 mmol
AutoPrep preparative HPLC
- AutoPrep 25 ~ 300 — up to 25 ~ 300 mL/min, 27.5 ~ 10 MPa
- AutoPrep1000 — 5 ~ 1,000 mL/min, 10 MPa
Other equipment — bioreactors · LNP production · analytical instruments · pumps and valves
- Nesto bioreactors, AutoMCD nanoparticle (LNP) production system, NestoPep150 peptide synthesizer
- Hicient L-2000 Bio HPLC · ISCE-1000 capillary electrophoresis, pump · valve components
What Inscinstech equipment does in the process
In biopharmaceutical downstream processing, chromatography separates the target substance from impurities, and TFF handles concentration and buffer exchange. Inscinstech makes equipment for these two steps at lab · pilot · production scale, and also supplies synthesizers and preparative HPLC for oligonucleotide drugs.
| Process Stage | Lab · process development | Pilot | Production |
|---|---|---|---|
| Column chromatography | AutoPreS · AutoPure (up to 15 ~ 300 mL/min) | Pilot600 · Pilot600D (1 ~ 600 mL/min per pump) | AutoPure Process (10 ~ 600 L/h) + IMC columns |
| Concentration · buffer exchange (TFF) | AutoTFF075 · AutoTFF3 (membranes up to 0.1 · 0.5 m²) | AutoTFF Pilot10 (0.1 ~ 2.5 m²) | AutoTFF Process (custom-built) |
| Oligo synthesis | MC-16 · AutoOligo 25 ~ 150 | AutoOligo 600 · 2000 | AutoOligo Process |
| Preparative purification (peptides · oligos · small molecules) | AutoPrep 25 ~ 300 | AutoPrep1000 | — |
Product lines by scale and scale-up
When the same manufacturer offers product lines at each scale, the software operation and record management are similar, which makes moving between them easier. However, sharing an equipment name does not mean a lab process can simply be scaled up as is. Scale-up suitability is reviewed together with column inner diameter · bed height · resin · residence time · pressure conditions.
- Lab → pilot: flow rates grow from mL/min to hundreds of mL/min, and columns with an inner diameter of 26 ~ 200 mm are operated (Pilot600 · 600D).
- Pilot → production: flow rates move to L/h, using a system with diaphragm pumps · flow meters · bubble traps · sanitary piping (AutoPure Process).
- The manufacturer's statements on GMP · 21 CFR Part 11 are the manufacturer's description. We receive the needed documents as a list and confirm what can be provided.
How the equipment relates in the oligo process
The manufacturer's oligo process solution divides the work into steps: synthesis (AutoOligo) → reversed-phase purification (AutoPrep) → ion-exchange purification (AutoPure · NestoPure) → concentration · desalting (AutoTFF). Equipment is chosen separately for each step; this does not mean it is supplied as a single connected, complete line.
TFF: automation scope differs by model
AutoTFF controls TMP and constant-volume diafiltration using inlet · retentate · permeate pressure and tank weight. Constant-volume diafiltration requires a transfer pump, and the AutoTFF075-L has no automatic pressure control valve or transfer pump. Membrane modules are chosen separately to suit the sample.
Selection Consultation Tailored to Your Process Conditions
Tell us as much as you know about your sample, throughput, columns or membranes, and current equipment, and B2BIO will use the manufacturer's materials to sort out models · options · items to prepare separately. You can start a consultation with just your sample and purpose, even without a model name. Demo format and schedule are arranged after the consultation.
Specification tables · comparison tables · resources by model: B2BIO Inscinstech product page ↗
Product Selection Information

Lab protein purification systems
Main Uses
- Purification of proteins · antibodies · nucleic acids · polysaccharides in research labs
- Gradient elution method development and purification automation
- Purification practice in university labs
Selection Criteria
- For small sample amounts with fixed conditions, the single-pump AutoPreS
- To develop · automate gradient conditions, the two-pump AutoPure, with flow rate 25 · 100 · 150 · 300 to match the column size
- To run multiple samples at once, the 8-channel NestoPure HT
Confirmed Specifications & Options
- UV: fixed wavelength standard, dual-wavelength · multi-wavelength (up to 190 ~ 800 nm) optional
- pH · pressure · bubble sensors optional
- Sample pump · buffer inlet · column · outlet valves optional
- Fraction collector: open · enclosed · cooled (6 ~ 20 ℃)
What to Tell Us
- Sample type and amount, purification step
- Columns in use and target flow rate
- Required measurements and fraction collection method

Pilot · production purification systems
Main Uses
- Pilot-scale review of purification methods established in the lab
- Purification of clinical samples · small batches
- Production-scale column chromatography
Selection Criteria
- Calculate the required flow rate from column inner diameter · bed height and linear velocity, then choose between Pilot600 (mL/min) and Process (L/h)
- If two columns · reverse-flow cleaning are needed, Pilot600D
- For GMP use, first list the documents you need
- Scale-up suitability is reviewed by column · resin · flow rate · pressure conditions, not by equipment name
Confirmed Specifications & Options
- Pilot600 · 600D: 1 ~ 600 mL/min per pump, 2 MPa, column inner diameter 26 ~ 200 mm
- AutoPure Process180 · 600: 10 ~ 180 · 10 ~ 600 L/h, 0 ~ 6 bar
- IMC columns: inner diameter 72 ~ 296 mm
What to Tell Us
- Process step and batch scale
- Column inner diameter · bed height · resin
- Target flow rate · pressure, required measurements
- Whether GMP use applies and the documents needed
Main Uses
- Concentration and buffer exchange (UF/DF) of proteins · antibodies · mRNA · viral vectors
- Clarification (microfiltration)
- TFF process development
Selection Criteria
- Choose tank size and model by process volume and concentration factor
- Choose the holder by membrane format and area
- For automated constant-volume diafiltration, choose a configuration that includes a transfer pump
- Automation scope differs by model, so check each model
Confirmed Specifications & Options
- AutoTFF075: 50 cm² ~ 0.1 m² (L has manual valves)
- AutoTFF3: 50 cm² ~ 0.5 m²
- Pilot10: 0.1 ~ 2.5 m²
- Membrane modules are selected separately
What to Tell Us
- Sample type · process volume · target concentration factor
- Membrane format · molecular weight cutoff · area you plan to use
- Whether automated DF and records are needed

Oligo synthesis · preparative HPLC
Main Uses
- Oligo synthesis such as siRNA · ASO
- Reversed-phase preparative purification after synthesis
- Preparative purification of peptides · small molecules
Selection Criteria
- Choose the synthesizer by synthesis scale (nmol ~ mmol) and number of sequences
- For preparative purification, choose the AutoPrep model by column inner diameter and throughput
- Concentration · desalting after purification is done separately with TFF
Confirmed Specifications & Options
- MC-16: 10 nmol ~ 20 µmol per column, 16 channels
- AutoOligo: 10 µmol ~ 1,800 mmol (by model)
- AutoPrep: up to 25 ~ 1,000 mL/min
What to Tell Us
- Target synthesis scale · sequence length · modifications
- Samples to purify, injection volume, columns
- Ventilation · gas conditions at the installation site
Installation examples
Equipment installed by B2BIO in a university biologics lab in Korea.