What Harvest and Clarification Does
Harvest and clarification is the step that removes cells, cell debris and smaller colloidal particles from the finished culture to produce a clear liquid that can enter the purification process.[2][4] In mammalian cell culture, a combination of centrifugation to remove cells followed by depth filtration to remove the remaining colloids is widely used as the standard approach.[1][3] Because centrifugation alone leaves very small particles behind, a filtration step follows it.[4][5]
Combining Centrifugation and Depth Filtration
- At small scale, depth filtration alone is often used; at larger scale, centrifugation is often placed ahead of it. Which option is better depends on cell density and cost, so there is no single answer that fits every process.[4][10]
- Depth filtration is usually arranged in two stages. An open-structured primary stage captures cells and large debris, and a tighter secondary stage captures colloids.[4][8]
- High shear at the centrifuge inlet breaks cells and generates submicron particles.[6] Broken cells release host cell proteins (HCP), DNA and proteases, which also increases the impurity burden.[5] Reducing these fine particles makes depth filtration easier, so centrifugation conditions are not set on solids removal efficiency alone.[6][15]
- When cell density is high and viability is low, turbidity and impurity burden increase, and the required filtration area becomes a constraint on scale-up.[1][8][9]
Tests That Set Depth Filter Capacity
- Depth filtration is usually operated at constant flux, so tests are also run at constant flux, recording the pressure rise against throughput volume.[3][16]
- The endpoint is set as a pressure limit. Published cases used limits of 15 psi and 2 bar, respectively, and took the throughput up to that point as the capacity.[3][8] Filtrate turbidity is also measured at set volume intervals to confirm that quality is maintained.[3][4]
- Area is set by multiplying the measured average capacity by a safety factor. Factor values differ between sources, so they are not adopted as is but set from the variability of your own process.[2][3][16]
- Results from small test devices may differ from those of large units. Even with the same media, it has been reported that internal flow distribution varies with device format and size, shifting the pressure rise and the point of DNA breakthrough.[9] Very small devices are not recommended for scale-up, and where possible, results are confirmed at two scales.[3][16]
How Much Soluble Impurity Removal to Expect
- Depth filter media usually consist of cellulose fibers, diatomaceous earth and a binder,[7][8] and in addition to size-based retention, they reduce some soluble impurities by adsorption.[7][8]
- However, binding depends on a protein's charge and hydrophobicity: positively charged, highly hydrophobic proteins bind well, while proteins near their isoelectric point bind very little.[7]
- For this reason, it is difficult to rely on depth filtration to reduce HCP and DNA. There are reports in which HCP was not significantly reduced by the primary filter,[8] and a comparison in which the depth filtrate showed the highest HCP.[2] The amount of DNA removed depends on the feed concentration, that is, on culture viability.[8]
- Because behavior changes when media composition or binder changes, a filter change is not evaluated on particle removal alone.[8][9]
Flushing, Extractables and Product Recovery
- Before use, water or buffer is flushed through to wash out loose particles and extractables from manufacturing.[4] In published cases, the pre-use flush volume is around 50 L/m².[2][3]
- β-Glucans released from cellulose media can cause false positives in LAL-based endotoxin assays.[13][14] When endotoxin values are unexplainably high, consider this possibility as well.[13]
- After use, the product remaining in the device is chased out with buffer and recovered.[4][17] Because the chase dilutes the product, when yield appears low, use a mass balance to distinguish actual loss from dilution.[18]
Before Passing to the Next Step
- The clarified fluid typically passes through a 0.2 µm or 0.1 µm filter to reduce bioburden and protect downstream columns from fouling.[1][4][8] Because this membrane is sensitive to the turbidity from the preceding step, the depth filtration endpoint is not judged by pressure alone.[4]
- Holding the harvest fluid for a long time can change product quality. Cases have been reported in which interchain disulfide bonds of antibodies were reduced by reducing enzymes (the thioredoxin family) released from lysed cells, and maintaining dissolved oxygen during harvest has been proposed as a countermeasure.[11][12] Define the hold time and air-exposure conditions in advance.[11][12]
- When cell density is too high for this combination, studies have used flocculation or chromatographic clarification.[1][2][15]
Harvest and Clarification Checklist
| Item to Check | What to Review |
|---|---|
| Combination | Centrifugation + depth filtration configuration matched to scale and density, primary and secondary roles [4][8][10] |
| Centrifugation Conditions | Shear-induced cell disruption and fine particles, load on downstream filtration [5][6][15] |
| Culture-Side Conditions | Cell density, viability and turbidity at harvest [1][8][9] |
| Capacity Testing | Constant flow rate, pressure endpoint, turbidity tracking [3][16] |
| Scale-Up | Effect of test device size and format, verification at two scales, safety factor [3][9][16] |
| Impurities | Adsorption is condition-dependent — measure HCP and DNA [7][8] |
| Flushing and Extractables | Pre-use flush volume, β-glucan and endotoxin testing [2][4][13] |
| Recovery | Post-use buffer chase, mass balance for dilution [4][17][18] |
| Downstream Steps | 0.2/0.1 µm filter, harvest hold time and dissolved oxygen [1][11][12] |
Sources
- Gimenez L, Kawkabani EE, Jacobs P, Malphettes L — Overcoming the clarification challenges of high cell density culture, BMC Proceedings 9(Suppl 9):P35
- Almeida A, Chau D, Coolidge T, El-Sabbahy H, Hager S, Jose K, Nakamura M, Voloshin A — Chromatographic capture of cells to achieve single stage clarification in recombinant protein purification, Biotechnology Progress 38(2)
- Noguchi M, Parampalli A, Abbott I, Setiabudi G, Chiruvolu V, Blanchard M, Lutz H — Considerations for Scaling-up Depth Filtration of Harvested Cell Culture Fluid, BioPharm International (2009)
- O'Brien TP, Brown LA, Battersby DG, Rudolph AS, Raman LP — Large-Scale, Single-Use Depth Filtration Systems, BioProcess International
- US Patent US 7,157,276 B2 (Biogen Idec) — Use of depth filtration in series with continuous centrifugation to clarify mammalian cell cultures
- Joseph A, Goldrick S, Mollet M, Turner R, Bender J, Gruber D, Farid SS — An automated laboratory-scale methodology for the generation of sheared mammalian cell culture samples, Biotechnology Journal 12(5) (2017)
- Nejatishahidein N, Borujeni EE, Roush DJ, Zydney AL — Effectiveness of host cell protein removal using depth filtration with a filter containing diatomaceous earth, Biotechnology Progress 36(6):e3028 (2020)
- Parau M, Pullen J, Bracewell DG — Depth filter material process interaction in the harvest of mammalian cells, Biotechnology Progress 39(3):e3329 (2023)
- Nejatishahidein N et al. — Scale-up issues for commercial depth filters in bioprocessing, Biotechnology and Bioengineering 119(4):1105–1114 (2022)
- Dryden WA, Larsen LM, Britt DW, Smith MT — Technical and economic considerations of cell culture harvest and clarification technologies, Biochemical Engineering Journal (2021), doi:10.1016/j.bej.2020.107892
- Hutterer KM, Hong RW, Lull J et al. — Monoclonal antibody disulfide reduction during manufacturing: Untangling process effects from product effects, mAbs 5(4):608–613 (2013)
- US Patent US 8,574,869 (Genentech) — Prevention of disulfide bond reduction during recombinant production of polypeptides
- Nelson Laboratories — Beta glucans: false positives in the Bacterial Endotoxins Test (BET)
- US Patent US 12,053,729 — Reduction of leachable beta-glucan levels from cellulose-containing filter materials
- McNerney T, Thomas A, Senczuk A et al. — PDADMAC flocculation of Chinese hamster ovary cells: Enabling a centrifuge-less harvest process for monoclonal antibodies, mAbs 7(2):413–427 (2015)
- Merck Millipore — Clarification Learning Center: Scale-up & Design Finalization / Optimization
- Cytiva — Depth filtration technical articles
- Pharmaceutical Manufacturing — Trouble Shooting Depth Filtration