Home › Guides › What to Check When Planning a Viral Clearance Study

What to Check When Planning a Viral Clearance Study

A viral clearance study demonstrates experimentally how much a manufacturing process reduces viruses. Based on ICH Q5A(R2), revised in 2023, this guide summarizes the items to check at the planning stage: selecting model viruses and scaled-down models, preliminary testing, the rules for adding up reduction values, and a design matched to the development stage.

QC & Biosafety Testing · Published 2026.11.23 · Last reviewed 2026.11.23

The Role of Viral Clearance Studies

The viral safety of biopharmaceuticals made from animal or human cells is assured by three complementary approaches: selecting and testing cell lines and raw materials for the absence of viruses, assessing the capacity of the process to clear viruses, and testing the product at appropriate stages of production.[1][5] A viral clearance study is the second of these, demonstrating experimentally how much the process steps reduce viruses.[1][9]

Reference Document: ICH Q5A(R2)

The second revision (R2) of the 1998 ICH Q5A was adopted by ICH on 1 November 2023.[4][11] The U.S. FDA issued it as final guidance in January 2024, and the EMA in Europe has applied it since 14 June 2024.[2][3][4] The revision extends the scope to viral vector products, adds content on continuous manufacturing and next-generation sequencing (NGS), and describes how to use prior knowledge from well-characterized platform processes.[4][5][6][7]

Selecting Model Viruses and Scaled-Down Models

  • The viruses to be tested are chosen to resemble viruses that could contaminate the product and to cover a wide range of physicochemical properties. When the actual virus is difficult to use, a closely related "model" virus is used instead.[1][8]
  • Viruses that are highly resistant to heat and chemical treatment are given priority. Small, non-enveloped parvoviruses (e.g., MVM) are commonly used as the most challenging case.[1][5][6]
  • Studies are performed with a scaled-down model of the actual manufacturing process, and the validity of the scaled-down model must be demonstrated. If residence time, pH or filtration conditions differ from the actual process, the results will not reflect actual performance.[1][7][8]

For a Valid Study: Spiking and Preliminary Testing

  • Virus is added to the sample in a small volume (spiking). Because the spike volume is limited, the amount and titer of the virus stock must be assessed in advance.[1][6]
  • Before the main study, it is confirmed separately that the buffers and product are not toxic to the cells used for the assay and do not interfere with the assay.[1][7][8]

Interpreting Results: Rules for Adding Up Reduction Values

The overall reduction for the process is usually expressed as the sum of the reduction values (log10) of the individual steps.[1][9] A reduction of about 1 log10 or less is not considered significant.[1][10] Steps with similar mechanisms (e.g., two low-pH treatments) are not added separately; instead, steps with different mechanisms are combined.[1][8] In addition, the amount of virus that could arise from the production cells (e.g., retrovirus-like particles counted by electron microscopy) is estimated to see whether the process can clear sufficiently more than that.[1][7]

Development Stage, Worst-Case Conditions and Resin Reuse

Study design is tailored to the product type, the process and the development stage.[6][7] In early clinical stages, the overall clearance capacity of the key steps is demonstrated; closer to licensure, more model viruses are added and it is shown that results hold at the edges of the process parameter ranges (worst-case conditions).[6][8] Chromatography resins are also considered, because their clearance capacity can change with repeated use.[1][6]

Test Planning Checklist

Item to CheckWhat to Review
Reference DocumentICH Q5A(R2), effective date in the region of submission [2][3]
Steps to ValidateWhether steps with different mechanisms (inactivation and removal) were selected [1][8]
Model VirusesWhether they represent potential contaminants, range of properties, inclusion of highly resistant viruses [1][6]
Scaled-Down ModelWhether residence time, pH and filtration conditions match the actual process; justification data [1][7]
Preliminary TestingCheck of sample cytotoxicity and interference, spike volume [1][7]
Calculating ResultsSum of step log10 values, exclusion of 1 log10 or less, no double counting of the same mechanism [1][10]
Stage and ConditionsDevelopment stage, worst-case conditions, effect of resin reuse [1][6][8]

Sources

  1. ICH Q5A (1998) — Viral Safety Evaluation of Biotechnology Products Derived From Cell Lines of Human or Animal Origin (Federal Register 63 FR 51074, 1998-09-24)
  2. U.S. FDA — Q5A(R2) Viral Safety Evaluation of Biotechnology Products Derived from Cell Lines of Human or Animal Origin (guidance page)
  3. EMA — ICH Q5A(R2) Guideline on viral safety evaluation of biotechnology products derived from cell lines of human or animal origin (guidance page)
  4. Bioprocess Online — Tim Sandle, Improving Viral Safety: Highlights Of ICH Q5A(R2), USP, Ph. Eur. Recommendations (2024-08-06)
  5. BioProcess International — Perez-Caballero, Murray, Niederlaender, Brorson, Viral Safety for Biotechnology Products Including Viral Vectors: ICH Q5A Revision 2 Brings Updated and More Comprehensive Guidance
  6. Minaris Advanced Testing (white paper) — Tailoring Viral Clearance Study Design to Regulatory Requirements and Real-World Demands
  7. BioProcess International — Kathleen Kenney, Optimizing Viral Clearance Studies: Practical Considerations for Detecting and Characterizing Process-Related Impurities
  8. BioPharm International — Rita C. Peters, Putting Viral Clearance Capabilities to the Test (2018-05-01)
  9. BioProcess International — Bao, Saini, Wang, Cheng, Dong, MAb Viral Clearance Studies: A Substantiated Platform Approach for the IND Stage (2021-10-28)
  10. WHO — Technical Report Series No. 924, Annex 4 Guidelines on viral inactivation and removal procedures intended to assure the viral safety of human blood plasma products (2004)
  11. PMDA — ICH Q5A(R2) final guideline
This article is a reference summary of published regulations, standards and papers, and does not recommend any particular product. When applying it to an individual process, follow the latest original text of the relevant regulation and the review of your quality unit.