A virus removal filter removes viruses by size difference. When selecting one, consider together the target to be retained (large or small viruses), the difference between manufacturer ratings and in-house validation, process conditions such as pressure, process interruptions and throughput, prefilters that reduce fouling, and sizing and integrity testing. This guide is based on ICH Q5A(R2) and published papers.

Filtration & Separation · Published 2026.11.23 · Last reviewed 2026.11.23

What a Virus Removal Filter Does

Virus removal filters retain viruses mainly by size difference (size exclusion).[4][6] They are much tighter than sterilizing-grade filters that remove bacteria, and are designed to let product molecules smaller than about 20 nm pass while retaining larger viruses.[6][11] The reference document for the viral safety of biopharmaceuticals is ICH Q5A(R2); the ICH final version was issued on 1 November 2023, and the U.S. FDA final guidance in January 2024.[1][2]

Large-Virus and Small-Virus Filters

  • Depending on the target, filters are divided into large-virus filters (e.g., retroviruses) and small-virus filters (e.g., parvoviruses).[4][7]
  • Because parvoviruses are among the smallest of the small viruses, an approach is used in which removal results shown with parvovirus on a small-virus filter are also applied to larger viruses.[3][4]
  • To harmonize performance claims that differed from filter to filter, PDA established a rating method using bacteriophages. The small-virus model is PP7, and the large-virus model is PR772.[7][8]
  • This rating is a value for comparing filters under standard conditions. Because actual removal capability varies with the product and solution conditions, it is validated with your own product in a scaled-down model of the actual process.[4][5]

Process Conditions Change Virus Removal

ICH Q5A(R2) regards the throughput of process fluid and buffer flush, pressure, and pressure and flow interruptions as conditions that can affect removal capability.[1][4] In studies, small-virus removal decreased in some cases at low pressure or after a process interruption (depressurization), and the extent varied with the filter type, the product, and pH and ionic strength.[4][5] Therefore, if the actual process includes interruptions, they are also included in the validation study.[5][12] The extent of flow decay due to fouling is another condition to examine.[4][6]

Reducing Fouling: Prefilters

  • Components similar in size to the filter pores, such as product aggregates, are considered a major cause of virus filter fouling.[6][13]
  • For this reason, placing an adsorptive prefilter upstream to capture aggregates and increase throughput is a common approach.[6][11][13]
  • Whether to use a prefilter, and which type is suitable, is determined by testing with the actual process fluid.[11][13]

Sizing and Integrity Testing

  • Process scale is determined from results obtained by filtering the actual process fluid through a small device, and the same scaled-down model serves as the basis for the validation study.[4][11]
  • Integrity tests include the gold particle test, bubble point, and air diffusion test; in production, the non-destructive air diffusion test is widely used.[9][10]
  • Integrity test acceptance values are meaningful only when they are linked to virus removal values.[9][10]
  • ICH Q5A(R2) calls for defining process controls so that filter replacement and post-use integrity testing can be carried out.[1][3]

Filter Selection Checklist

Item to CheckWhat to Review
Retention TargetLarge-virus or small-virus filter, parvovirus removal data [3][4][7]
Rating DataBacteriophage rating (PP7, PR772) and test conditions [7][8]
Process ConditionsThroughput, flush volume, pressure, presence of interruptions [1][4][5]
In-House ValidationScaled-down model, actual product, process interruptions included [4][5]
FoulingFlow decay, aggregates, need for a prefilter [6][13]
Integrity TestingTest method, link to virus removal values, post-use testing [1][9][10]

Sources

  1. ICH — Q5A(R2) Viral Safety Evaluation of Biotechnology Products Derived from Cell Lines of Human or Animal Origin
  2. U.S. FDA — Guidance for Industry: Q5A(R2) Viral Safety Evaluation …
  3. Perez-Caballero D, Murray D, Niederlaender C, Brorson K — Viral Safety for Biotechnology Products, Including Viral Vectors: ICH Q5A Revision 2 Brings Updated and More Comprehensive Guidance, BioProcess International
  4. Gröner A — Virus Retentive Filters – Effective Virus Removal in the Manufacturing Process of Biologicals, Medical Research Archives (2024-12)
  5. Strauss D et al. — Characterizing the impact of pressure on virus filtration processes and establishing design spaces to ensure effective parvovirus removal, Biotechnology Progress 33(5):1294–1302 (2017)
  6. Isu S, Qian X, Zydney AL, Wickramasinghe SR — Process- and Product-Related Foulants in Virus Filtration, Bioengineering 9(4):155 (2022)
  7. PDA — ANSI/PDA Standard 04-2021, Phage Retention Nomenclature Rating for Small- and Large-Virus Retentive Filters
  8. PDA Journal of Pharmaceutical Science and Technology 62(5):334 (2008) — PDA Virus Filter Task Force rating method study
  9. Jang H, Saxena L, Kim S, Lee J, Jin Y — Influence of Air-Diffusion Value Shifts on Virus-Clearance Values, BioProcess International (2024-10-15)
  10. Sekine S, Komuro M, Sohka T, Sato T — Integrity testing of … virus removal filters used in the manufacture of biological products, Biologicals (2015)
  11. Roederstein S, Thom V — Virus Filtration Using a High-Throughput Parvovirus-Retentive Membrane, BioPharm International (2013)
  12. Cytiva — Virus filtration for virus removal
  13. MilliporeSigma — Virus filtration process development (RP5758)
This article is a reference summary of published regulations, standards and papers, and does not recommend any particular product. When applying it to an individual process, follow the latest original text of the relevant regulation and the review of your quality unit.
Operated by B2BIO Inc., Bioprocess Division · Report content errors to info@b2bio.co.kr

Talk to us about this topic

Tell us the topic of this article and the conditions you are working with now, and we will point you to suitable products and documents.

Talk to us about this topic
↑